Schneider Electric Smart Panels for Power Distribution

£2,500.00

Applications

  • Power plant;
  • Data logging;
  • Load analysis;
  • Power quality analysis;
  • Power monitoring system;
  • Mobile communication company;
  • Medium and low voltage systems;
  • Electric energy metering cabinet;
  • Low voltage distribution cabinet;
  • High voltage distribution cabinet;
  • Energy consumption monitoring system;
  • Commercial, industrial, power electricity utility;
  • Electric energy metering of photovoltaic power station;
  • Metering of distribution feeders, transformers, generators, capacitor banks and motors
Add to Wishlist
Add to Wishlist

Description

What is a Smart Panel?

I think many of us already know that efficient energy management is crucial in the modern world. With rising electricity costs and the need to generate sustainability, solutions like Schneider Electric’s Smart Panel system become indispensable. But what exactly is a Smart Panel and how can it benefit you?

Schneider Electric Smart Panels are an integrated hardware and software solution that provides total visibility and control over the distribution and consumption of energy in buildings, industries, premises and even homes. This system is designed not only to monitor and control energy, but also to optimize its use, improve efficiency and ensure the reliability of the electrical infrastructure. It will allow us to generate multiple consumption and optimization data in real time and we will even be able to program, control and act remotely on the various protections and devices that make up our Smart Panel.

Components of a Smart Panel

 

 

As you can see in the picture, this Smart Panel is composed of different modules. The equipment that is present in a Smart Panel includes smart meters, circuit breakers and communication devices, which can be controlled and managed remotely thanks to their connection to a master device or HUB, which we will be discussing in detail in future articles. All these devices work together to offer you high security and efficient energy management. It should be noted that each of the components has a crucial role to play, ranging from data collection to the execution of automatic actions to correct any irregularities.

Schneider Electric Smart Panels Key Features

 

 

Real Time Monitoring

First, there is real-time monitoring. The Smart Panel enables continuous monitoring of all electrical parameters and system performance, providing instant data on energy consumption and the status of electrical management equipment and protections. This means you can detect any anomalies or inefficiencies as they occur, allowing you to take immediate corrective action.

Energy Analysis

Next, we have energy analysis. This system generates detailed reports and analysis on energy usage, helping you identify opportunities to improve efficiency. Imagine being able to see in detail how and when energy is consumed in your circuits, and using all that information to optimize your processes and reduce costs.

Energy Management

Third is energy management, as a Smart Panel facilitates demand management and peak load reduction, implementing effective energy saving strategies. With this system, you can schedule and control energy use to avoid costly electricity peaks, distributing the load more evenly throughout the day.

Features

  • 4 quadrant energy;
  • Three years warranty;
  • Power quality analysis;
  • Web browse data function;
  • With load curve function;
  • Unbalance & phase angles;
  • Max/Min log with timestamp;
  • With PC management software;
  • True-RMS measuring parameters;
  • Demands and Multi-tariff energy;
  • Standard panel 96*96 installation;
  • 2MB onboard memory, Extended to 16M;
  • TOU, 4 Tariffs, 6 Seasons, 6 Schedules;
  • High-speed RS485, 10/100M Ethernet port;
  • ANSI and IEC 0.2 or 0.5S accuracy class;
  • Support RTU-Modbus, TCP/IP, SNMP protocol;
  • High precision active energy meter function;
  • Data logging for all electrical parameters;
  • Time interval set from 1minute to 60minutes;
  • Measure individual harmonics from 2nd to 63rd
Power Supply (AC/DC) AC 85-400V / DC 85-330V
Power consumption: <4VA
Accuracy class 0.5s
Measurement Parameters Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Phase angle; Active power(W); Reactive power(Q); Apparent power(S), 2nd to 63rd harmonics(option)
Harmonics Total harmonics ratio of phase-voltage
Total harmonics ratio of current
2nd to 63rd harmonics ratio of phase-voltage
2nd to 63rd harmonics ratio of current
Maximum Value & Minimum Value Voltage, current, frequency, active power, reactive power, apparent power,demandP,demandQ, demandS.
Computation Forward active power energy
Reverse active power energy
Forward active power energy
Reverse reactive power energy
Measuring Range 0-480V(P-N), 0-800V(P-P), 0-10A, 45-65Hz, -1 ~ 0 ~ 1
Measuring Accuracy Voltage: 0.5%RD±0.05%FS
Current: 0.5%RD±0.05%FS
Active power: 0.5%RD±0.05%FS
Reactive power: 1.5%RD +0.05%FS
Apparent power: 0.5%RD +0.1%FS
Power factor: 0.5%RD
Frequency: 0.05%RD
Active energy: 0.5S, 0.5% , 1%
Maximum Demand Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Data logger interval time 1minute – 60 minutes can be set
Data logger U1,U2,U3, U12,U23,U31, I1,I2,I3, F, P,Q,S, demand, Ep Eq, Es, Phase,Unbalance,EPrate, EQrate, ESrate
Load recorder or curve Yes
Display Blue back-lit LCD Display
5 display figures
4 operation keys
Communication Support RS-485 interface port, 32 (128) Networking
RTU-ModBus-TCP/IP, SNMP communication protocol
Ethernet 10/100M port (RJ45)
Memory 2M onboard memory,can be extended to 16M.
Data looger interval can set by end users from 1min to 60min.The default is 15min.
You can read the data through a PC, also you can select the data to diaplay and store from software.
Programmable Measuring system: 3P4W/3P3W etc
Transformation Ratio: PT 1-10000; CT 1-10000
Energy Pulse Provides active & reactive energy pulse output
Pulse parameters can be choosed
Pulse constant range: 0.1-10000kWh/kvarh
Pulse constant can be programmable
Dry contact output (1Ax100V)
Input every voltage/current compsumption 0.5VA/channel
Tariffs 4
Seasons 6
Schedules 6
Connection Mode 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W
Clock Yes
Baud 1200-57600, Standard 38400
Web browser Yes
PC management software Yes, downloaddata to excel file
Standard
Standard IEC 62053-21,22, 23, 24; ANSI C12.20; IEC 62052-11; IEC 62586-2; IEC 61326-1; IEC 61000-4-30: class S; IEEE 519: 2014; EN 50160: 2010; IEC 61557-12; EN61010-2-030:2010; EN61326-1:2013; EN61000-3-2:2014; EN61000-3-3:2013; IEC61557-12; IEC60068-2-1/2/30
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP42
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (L x W x H) (mm) 96 x 96 x 14
Net Weight 550g
Mounting Panel mounting
Trepanning: 92x92mm
The thickness of installation: 84mm
DIN mounting (optional)
Environmental conditions
Temperature -5 to +50 °C
Humidity 20%-95%RH, without condensation
Warranty Three years warranty

Index

Parameters Accuracy Resolution Measuring range Show on the display
Voltage 0.2% 0.01V 0-400V 0.5-500kV
Current 0.2% 0.01mA 0-6.5A 1mA-50000A
Active power 0.5% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive power 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent power 0.5% 0.2VA 0-2400VA/phase 0-9999MVA
Active demand 0.5% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive demand 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent demand 0.5% 0.2VA 0-2400VA/phase 0 to 9999MVA
Apparent demand 0.5% 0.2VA 0-2400VA/phase 0 to 9999MVA
Power factor 0.005 0.0001 -1.000 – 0 – 1.000 -1.000 – 0 – 1.000
Frequency 0.01Hz 0.01Hz 45.000-65.000Hz 45.000-65.000Hz
Active energy 0.5S, 0.5%, 0.2% 0.001kWh 0-999999.999kWh 0-99999999.9kWh
Reactive energy 2% 0.001kvarh 0-999999.999kvarh 0-99999999.9kvarh
Apparent energy 0.5% 0.001VAh 0-999999.999kVAh 0-99999999.9kVAh
Phase angle 0.1° 0.01° 0-359.99° 0-359.99°
Unbalance 2% 0.01% 0-300.00% 0-300.00%
PT ratio 1 1-10000
CT ratio 1 1-10000
Address code 1 1-253
9
    9
    Your Cart

    Contact Now